Installation requirements of molten salt submerged pump

    Installation requirements of molten salt submerged pump
    1. Molten salt pump must be installed vertically on the fixed support of the molten salt pond (tank). And bolts or other means are used to fasten molten salt pump bottom plate and a fixed bracket.

    2,The distance that it is from suction inlet to the bottom of the pool for the molten salt liquid pump should be more than 2 times the distance of the inlet diameter.
    3, The outlet pipe of the molten salt liquid pump must be set up the support and it does not allow the pump to bear the weight of the export pipeline.