The vibration detectors of the molten salt pump
Two (2) (X and Y axes) vibration detectors at each pump radial bearing.
Two (2) (X and Y axes) vibration detectors at pump thrust bearing.
One (1) double PT-100, three wires at each pump bearing
One (1) 4-20 mA transmitter associated with each temperature sensor (only one PT-100 shall be connected to the temperature transmitter per bearing, leaving the other as a spare, with its terminals easily accessible).