Instrumentation and controls of the molten salt system
The instrunentation and controls required t o monitor and regulate such test parmeters as salt pump flow, salt temperature, pressure, and level will be supplied. Salt flow will be regulated with a throttling valve and measured with a xodified flow nozzle. Temperature will be measured with stainless steel sheatked Chromel-Alumel thermocouples. Sealed high-temperature transmit.ters w i l l be used t o measure circulating salt pressures.