Reason and elimination method of flow rate of molten salt pu

release time:2017/01/04 clicks:

    Reason and elimination method of flow rate of molten salt pump
    Molten salt pump in the use of the process, the user may find no flow, especially in the molten salt pump in the process of debugging, is now summed up the common causes and elimination methods.
    1. The suction pipe or import may is the depth of molten salt pump liquid choice is not appropriate, resulting in pump inlet away from the molten salt bath floor distance is too low, in imports is not smooth or blockage in the. Fault removing method is eliminating the clogging phenomenon.
    2 molten salt level is lower than the work of the impeller can’t normally start the pump, this time should be as soon as possible to add molten salt bath salt, and to start the molten salt heating system.
    3 molten salt system containing air in the pipeline, resulting in molten salt pump can’t drive. Should be excluded from the pipeline gas and check the molten salt pump pipeline design is flawed.
    4 motor turn to lead to the molten salt pump impeller reverse, should change the motor to turn.
    5 molten salt tank in the molten salt is completely melted.