Design parameters of the submerged pump

release time:2017/01/13 clicks:

Design parameters of the submerged  pump

    Design parameters of the submerged  pump
    For the submerged  pump, before you design the hydraulic design, you should need to understand the performance parameters of the pump, the use of occasions, special requirements and so on. So you need to understand the purpose of the design.

Flow Q

50

Unit:m3/h

Head H

30

Unit: m

Speed n

1450

Unit: rpm(r/min)

efficiency

65

The efficiency of the design

medium

Molten salt

Temperature, weight, the condition of concluding the magazine,

device cavitation

3.3

Geometric suction height, unit: m

Characteristic curve

High efficiency

Requirements flat, steep drop, no overload (full head) and high efficiency

    If the medium characteristic of the submerged  pump is different from the water, when it is designing  the hydraulic, you should consider other factors, such as viscosity characteristics.